# TMC2240 configuration # import math, logging from . import bus, tmc, tmc_uart, tmc2130 TMC_FREQUENCY=10000000. Registers = { "GCONF": 0x00, "GSTAT": 0x01, "IFCNT": 0x02, "SLAVECONF": 0x03, "IOIN": 0x04, "DRV_CONF": 0x0A, "GLOBALSCALER": 0x0B, "IHOLD_IRUN": 0x10, "TPOWERDOWN": 0x11, "TSTEP": 0x12, "TPWMTHRS": 0x13, "TCOOLTHRS": 0x14, "THIGH": 0x15, "DIRECT_MODE": 0x2d, "ENCMODE": 0x38, "X_ENC": 0x39, "ENC_CONST": 0x3a, "ENC_STATUS": 0x3b, "ENC_LATCH": 0x3c, "ADC_VSUPPLY_AIN": 0x50, "ADC_TEMP": 0x51, "OTW_OV_VTH": 0x52, "MSLUT_0": 0x60, "MSLUT_1": 0x61, "MSLUT_2": 0x62, "MSLUT_3": 0x63, "MSLUT_4": 0x64, "MSLUT_5": 0x65, "MSLUT_6": 0x66, "MSLUT_7": 0x67, "MSLUTSEL": 0x68, "MSLUTSTART": 0x69, "MSCNT": 0x6a, "MSCURACT": 0x6b, "CHOPCONF": 0x6c, "COOLCONF": 0x6d, "DRV_STATUS": 0x6f, "PWMCONF": 0x70, "PWM_SCALE": 0x71, "PWM_AUTO": 0x72, # "SG4_THRS": 0x74, "SGTHRS": 0x74, "SG4_RESULT": 0x75, "SG4_IND": 0x76 } ReadRegisters = [ "GCONF", "CHOPCONF", "GSTAT", "DRV_STATUS", "IOIN", "MSCNT", "MSCURACT", "PWM_SCALE", "PWM_AUTO", "IFCNT" ] Fields = {} Fields["GCONF"] = { "fast_standstill": 0x01 << 1, "en_pwm_mode": 0x01 << 2, "multistep_filt": 0x01 << 3, "shaft": 0x01 << 4, "diag0_error": 0x01 << 5, "diag0_otpw": 0x01 << 6, "diag0_stall": 0x01 << 7, "diag1_stall": 0x01 << 8, "diag1_index": 0x01 << 9, "diag1_onstate": 0x01 << 10, "diag0_pushpull": 0x01 << 12, "diag1_pushpull": 0x01 << 13, "small_hysteresis": 0x01 << 14, "stop_enable": 0x01 << 15, "direct_mode": 0x01 << 16, } Fields["GSTAT"] = { "reset": 0x01 << 0, "drv_err": 0x01 << 1, "uv_cp": 0x01 << 2, "register_reset": 0x01 << 3, "vm_uvlo": 0x01 << 4 } Fields["IOIN"] = { "step": 0x01 << 0, "dir": 0x01 << 1, "encb": 0x01 << 2, "enca": 0x01 << 3, "drv_enn": 0x01 << 4, "encn": 0x01 << 5, "uart_en": 0x01 << 6, "reserved": 0x01 << 7, "comp_a": 0x01 << 8, "comp_b": 0x01 << 9, "comp_a1_a2": 0x01 << 10, "comp_b1_b2": 0x01 << 11, "version": 0xff << 24 } Fields["GLOBALSCALER"] = { "globalscaler": 0xff << 0 } Fields["IHOLD_IRUN"] = { "ihold": 0x1f << 0, "irun": 0x1f << 8, "iholddelay": 0x0f << 16, "irundelay": 0x0f << 24 } Fields["TPOWERDOWN"] = { "tpowerdown": 0xff } Fields["TSTEP"] = { "tstep": 0xfffff << 0 } Fields["TPWMTHRS"] = { "tpwmthrs": 0xfffff << 0 } Fields["TCOOLTHRS"] = { "tcoolthrs": 0xfffff << 0 } Fields["THIGH"] = { "thigh": 0xfffff << 0 } Fields["DIRECT_MODE"] = { "direct_coil_a": 0x1ff << 0, "direct_coil_b": 0x1ff << 16 } Fields["ENCMODE"] = { "pol_a": 0x01 << 0, "pol_b": 0x01 << 1, "pol_n": 0x01 << 2, "ignore_ab": 0x01 << 3, "clr_cont": 0x01 << 4, "clr_once": 0x01 << 5, "pos_neg_edge": 0x03 << 6, "clr_enc_x": 0x01 << 8, "enc_sel_decimal": 0x01 << 10 } Fields["X_ENC"] = { "x_enc": 0xffffffff << 0 } Fields["ENC_CONST"] = { "enc_const": 0xffffffff << 0 } Fields["ENC_STATUS"] = { "n_event": 0x01 << 0 } Fields["ENC_LATCH"] = { "enc_latch": 0xffffffff << 0 } Fields["MSLUT_0"] = { "mslut_0": 0xffffffff << 0 } Fields["MSLUT_1"] = { "mslut_1": 0xffffffff << 0 } Fields["MSLUT_2"] = { "mslut_2": 0xffffffff << 0 } Fields["MSLUT_3"] = { "mslut_3": 0xffffffff << 0 } Fields["MSLUT_4"] = { "mslut_4": 0xffffffff << 0 } Fields["MSLUT_5"] = { "mslut_5": 0xffffffff << 0 } Fields["MSLUT_6"] = { "mslut_6": 0xffffffff << 0 } Fields["MSLUT_7"] = { "mslut_7": 0xffffffff << 0 } Fields["MSLUTSEL"] = { "w0": 0x03 << 0, "w1": 0x03 << 2, "w2": 0x03 << 4, "w3": 0x03 << 6, "x1": 0xff << 8, "x2": 0xff << 16, "x3": 0xff << 24 } Fields["MSLUTSTART"] = { "start_sin": 0xff << 0, "start_sin90": 0xff << 16, "offset_sin90": 0xff << 24 } Fields["MSCNT"] = { "mscnt": 0x3ff << 0 } Fields["MSCURACT"] = { "cur_b": 0x1ff << 0, "cur_a": 0x1ff << 16 } Fields["CHOPCONF"] = { "toff": 0x0F << 0, "hstrt": 0x07 << 4, "hend": 0x0F << 7, "fd3": 0x01 << 11, "disfdcc": 0x01 << 12, "chm": 0x01 << 14, "tbl": 0x03 << 15, "vhighfs": 0x01 << 18, "vhighchm": 0x01 << 19, "tpfd": 0x0F << 20, # midrange resonances "mres": 0x0F << 24, "intpol": 0x01 << 28, "dedge": 0x01 << 29, "diss2g": 0x01 << 30, "diss2vs": 0x01 << 31 } Fields["COOLCONF"] = { "semin": 0x0f << 0, "seup": 0x03 << 5, "semax": 0x0f << 8, "sedn": 0x03 << 13, "seimin": 0x01 << 15, "sgt": 0x7f << 16, "sfilt": 0x01 << 24 } Fields["DRV_STATUS"] = { "sg_result": 0x3FF << 0, "s2vsa": 0x01 << 12, "s2vsb": 0x01 << 13, "stealth": 0x01 << 14, "fsactive": 0x01 << 15, "csactual": 0xFF << 16, "stallguard": 0x01 << 24, "ot": 0x01 << 25, "otpw": 0x01 << 26, "s2ga": 0x01 << 27, "s2gb": 0x01 << 28, "ola": 0x01 << 29, "olb": 0x01 << 30, "stst": 0x01 << 31 } Fields["PWMCONF"] = { "pwm_ofs": 0xFF << 0, "pwm_grad": 0xFF << 8, "pwm_freq": 0x03 << 16, "pwm_autoscale": 0x01 << 18, "pwm_autograd": 0x01 << 19, "freewheel": 0x03 << 20, "pwm_meas_sd_enable": 0x01 << 22, "pwm_dis_reg_stst": 0x01 << 23, "pwm_reg": 0x0F << 24, "pwm_lim": 0x0F << 28 } Fields["PWM_SCALE"] = { "pwm_scale_sum": 0xff << 0, "pwm_scale_auto": 0x1ff << 16 } Fields["IFCNT"] = { "ifcnt": 0xff } ''' Fields["SG4_THRS"] = { "sg4_thrs": 0xff, "sg4_filt_en": 0x01 << 8, "sg4_angle_offset": 0x01 << 9 } ''' Fields["SGTHRS"] = { "sgthrs": 0xff, "sg4_filt_en": 0x01 << 8, "sg4_angle_offset": 0x01 << 9 } Fields["SG4_RESULT"] = { "sg4_result": 0x3ff << 9 } Fields["DRV_CONF"] = { "current_range": 0x03 << 0, "slope_control": 0x03 << 4, } Fields["OTW_OV_VTH"] = { "overtempperwarning_vth": 0x1ff << 16 } SignedFields = ["cur_a", "cur_b", "sgt", "pwm_scale_auto"] FieldFormatters = dict(tmc2130.FieldFormatters) ###################################################################### # TMC stepper current config helper ###################################################################### MAX_CURRENT = 2.000 class TMC2240CurrentHelper: def __init__(self, config, mcu_tmc): self.printer = config.get_printer() self.name = config.get_name().split()[-1] self.mcu_tmc = mcu_tmc self.fields = mcu_tmc.get_fields() run_current = config.getfloat('run_current', above=0., maxval=MAX_CURRENT) hold_current = config.getfloat('hold_current', MAX_CURRENT, above=0., maxval=MAX_CURRENT) self.req_hold_current = hold_current self._set_globalscaler(run_current) irun, ihold = self._calc_current(run_current, hold_current) self.fields.set_field("ihold", ihold) self.fields.set_field("irun", irun) # self.fields.set_field("irun", 31) def _set_globalscaler(self, current): globalscaler = int((current * 256. * math.sqrt(2.) / 2.0 + .5)) globalscaler = max(32, globalscaler) if globalscaler >= 256: globalscaler = 0 self.fields.set_field("globalscaler", globalscaler) # self.fields.set_field("globalscaler", 0) def _calc_current_bits(self, current): globalscaler = self.fields.get_field("globalscaler") if not globalscaler: globalscaler = 256 cs = int((current * 256. * 32. * math.sqrt(2.)) / (3. * globalscaler) -1. + .5) return max(0, min(31, cs)) def _calc_current(self, run_current, hold_current): irun = self._calc_current_bits(run_current) ihold = self._calc_current_bits(min(hold_current, run_current)) return irun, ihold def _calc_current_from_field(self, field_name): globalscaler = self.fields.get_field("globalscaler") if not globalscaler: globalscaler = 256 bits = self.fields.get_field(field_name) return (globalscaler * (bits + 1) * 0.325 / (256. * 32. * math.sqrt(2.))) def get_current(self): run_current = self._calc_current_from_field("irun") hold_current = self._calc_current_from_field("ihold") return run_current, hold_current, self.req_hold_current, MAX_CURRENT def set_current(self, run_current, hold_current, print_time): self.req_hold_current = hold_current irun, ihold = self._calc_current(run_current, hold_current) self.fields.set_field("ihold", ihold) val = self.fields.set_field("irun", irun) # self.printer.command_error("val = %d, print_time = ", val, print_time) self.mcu_tmc.set_register("IHOLD_IRUN", val, print_time) ###################################################################### # TMC2240 printer object ###################################################################### class TMC2240: def __init__(self, config): # Setup mcu communication self.fields = tmc.FieldHelper(Fields, SignedFields, FieldFormatters) self.mcu_tmc = tmc2130.MCU_TMC_SPI(config, Registers, self.fields) # self.mcu_tmc = tmc_uart.MCU_TMC_uart(config, Registers, self.fields, 4) # Setup fields for UART # self.fields.set_field("uart_en", True) # Allow virtual pins to be created tmc.TMCVirtualPinHelper(config, self.mcu_tmc) # Register commands current_helper = TMC2240CurrentHelper(config, self.mcu_tmc) cmdhelper = tmc.TMCCommandHelper(config, self.mcu_tmc, current_helper) cmdhelper.setup_register_dump(ReadRegisters) self.get_phase_offset = cmdhelper.get_phase_offset self.get_status = cmdhelper.get_status # Setup basic register values # tmc.TMCStealthchopHelper(config, self.mcu_tmc, TMC_FREQUENCY) tmc.TMC2240StealthchopHelper(config, self.mcu_tmc, TMC_FREQUENCY) set_config_field = self.fields.set_config_field # set_config_field(config, "en_pwm_mode", 1) set_config_field(config, "reset", 1) set_config_field(config, "drv_err", 1) set_config_field(config, "uv_cp", 1) set_config_field(config, "register_reset", 1) set_config_field(config, "vm_uvlo", 1) # set_config_field(config, "tpwmthrs", 100) # set_config_field(config, "intpol", 0) # set_config_field(config, "dedge", 0) # set_config_field(config, "disfdcc", 1) set_config_field(config, "toff", 3) set_config_field(config, "hstrt", 5) set_config_field(config, "hend", 2) set_config_field(config, "fd3", 0) set_config_field(config, "disfdcc", 0) set_config_field(config, "chm", 0) set_config_field(config, "tbl", 2) set_config_field(config, "vhighfs", 0) set_config_field(config, "vhighchm", 0) set_config_field(config, "tpfd", 4) set_config_field(config, "diss2g", 0) set_config_field(config, "diss2vs", 0) set_config_field(config, "semin", 0) set_config_field(config, "seup", 0) set_config_field(config, "semax", 0) set_config_field(config, "sedn", 0) set_config_field(config, "seimin", 0) set_config_field(config, "sgt", 0) set_config_field(config, "sfilt", 0) set_config_field(config, "iholddelay", 6) set_config_field(config, "pwm_ofs", 30) set_config_field(config, "pwm_grad", 0) set_config_field(config, "pwm_freq", 0) set_config_field(config, "pwm_autoscale", True) set_config_field(config, "pwm_autograd", True) set_config_field(config, "freewheel", 0) set_config_field(config, "pwm_reg", 4) set_config_field(config, "pwm_lim", 12) set_config_field(config, "tpowerdown", 10) set_config_field(config, "current_range", 2) set_config_field(config, "overtempperwarning_vth", 0x1ff) def load_config_prefix(config): return TMC2240(config)