mirror of
https://github.com/QIDITECH/klipper.git
synced 2026-01-30 23:48:43 +03:00
klipper update
This commit is contained in:
388
klippy/klippy.py
Normal file
388
klippy/klippy.py
Normal file
@@ -0,0 +1,388 @@
|
||||
#!/usr/bin/env python2
|
||||
# Main code for host side printer firmware
|
||||
#
|
||||
# Copyright (C) 2016-2020 Kevin O'Connor <kevin@koconnor.net>
|
||||
#
|
||||
# This file may be distributed under the terms of the GNU GPLv3 license.
|
||||
import sys, os, gc, optparse, logging, time, collections, importlib
|
||||
import util, reactor, queuelogger, msgproto
|
||||
import gcode, configfile, pins, mcu, toolhead, webhooks
|
||||
|
||||
message_ready = "Printer is ready"
|
||||
|
||||
message_startup = """
|
||||
Printer is not ready
|
||||
The klippy host software is attempting to connect. Please
|
||||
retry in a few moments.
|
||||
"""
|
||||
|
||||
message_restart = """
|
||||
Once the underlying issue is corrected, use the "RESTART"
|
||||
command to reload the config and restart the host software.
|
||||
Printer is halted
|
||||
"""
|
||||
|
||||
message_protocol_error1 = """
|
||||
This is frequently caused by running an older version of the
|
||||
firmware on the MCU(s). Fix by recompiling and flashing the
|
||||
firmware.
|
||||
"""
|
||||
|
||||
message_protocol_error2 = """
|
||||
Once the underlying issue is corrected, use the "RESTART"
|
||||
command to reload the config and restart the host software.
|
||||
"""
|
||||
|
||||
message_mcu_connect_error = """
|
||||
Once the underlying issue is corrected, use the
|
||||
"FIRMWARE_RESTART" command to reset the firmware, reload the
|
||||
config, and restart the host software.
|
||||
Error configuring printer
|
||||
"""
|
||||
|
||||
message_shutdown = """
|
||||
Once the underlying issue is corrected, use the
|
||||
"FIRMWARE_RESTART" command to reset the firmware, reload the
|
||||
config, and restart the host software.
|
||||
Printer is shutdown
|
||||
"""
|
||||
|
||||
class Printer:
|
||||
config_error = configfile.error
|
||||
command_error = gcode.CommandError
|
||||
def __init__(self, main_reactor, bglogger, start_args):
|
||||
self.bglogger = bglogger
|
||||
self.start_args = start_args
|
||||
self.reactor = main_reactor
|
||||
self.reactor.register_callback(self._connect)
|
||||
self.state_message = message_startup
|
||||
self.in_shutdown_state = False
|
||||
self.run_result = None
|
||||
self.event_handlers = {}
|
||||
self.objects = collections.OrderedDict()
|
||||
# Init printer components that must be setup prior to config
|
||||
for m in [gcode, webhooks]:
|
||||
m.add_early_printer_objects(self)
|
||||
def get_start_args(self):
|
||||
return self.start_args
|
||||
def get_reactor(self):
|
||||
return self.reactor
|
||||
def get_state_message(self):
|
||||
if self.state_message == message_ready:
|
||||
category = "ready"
|
||||
elif self.state_message == message_startup:
|
||||
category = "startup"
|
||||
elif self.in_shutdown_state:
|
||||
category = "shutdown"
|
||||
else:
|
||||
category = "error"
|
||||
return self.state_message, category
|
||||
def is_shutdown(self):
|
||||
return self.in_shutdown_state
|
||||
def _set_state(self, msg):
|
||||
if self.state_message in (message_ready, message_startup):
|
||||
self.state_message = msg
|
||||
if (msg != message_ready
|
||||
and self.start_args.get('debuginput') is not None):
|
||||
self.request_exit('error_exit')
|
||||
def add_object(self, name, obj):
|
||||
if name in self.objects:
|
||||
raise self.config_error(
|
||||
"Printer object '%s' already created" % (name,))
|
||||
self.objects[name] = obj
|
||||
def lookup_object(self, name, default=configfile.sentinel):
|
||||
if name in self.objects:
|
||||
return self.objects[name]
|
||||
if default is configfile.sentinel:
|
||||
raise self.config_error("Unknown config object '%s'" % (name,))
|
||||
return default
|
||||
def lookup_objects(self, module=None):
|
||||
if module is None:
|
||||
return list(self.objects.items())
|
||||
prefix = module + ' '
|
||||
objs = [(n, self.objects[n])
|
||||
for n in self.objects if n.startswith(prefix)]
|
||||
if module in self.objects:
|
||||
return [(module, self.objects[module])] + objs
|
||||
return objs
|
||||
def load_object(self, config, section, default=configfile.sentinel):
|
||||
if section in self.objects:
|
||||
return self.objects[section]
|
||||
module_parts = section.split()
|
||||
module_name = module_parts[0]
|
||||
py_name = os.path.join(os.path.dirname(__file__),
|
||||
'extras', module_name + '.py')
|
||||
py_dirname = os.path.join(os.path.dirname(__file__),
|
||||
'extras', module_name, '__init__.py')
|
||||
if not os.path.exists(py_name) and not os.path.exists(py_dirname):
|
||||
if default is not configfile.sentinel:
|
||||
return default
|
||||
raise self.config_error("Unable to load module '%s'" % (section,))
|
||||
mod = importlib.import_module('extras.' + module_name)
|
||||
init_func = 'load_config'
|
||||
if len(module_parts) > 1:
|
||||
init_func = 'load_config_prefix'
|
||||
init_func = getattr(mod, init_func, None)
|
||||
if init_func is None:
|
||||
if default is not configfile.sentinel:
|
||||
return default
|
||||
raise self.config_error("Unable to load module '%s'" % (section,))
|
||||
self.objects[section] = init_func(config.getsection(section))
|
||||
return self.objects[section]
|
||||
def _read_config(self):
|
||||
self.objects['configfile'] = pconfig = configfile.PrinterConfig(self)
|
||||
config = pconfig.read_main_config()
|
||||
if self.bglogger is not None:
|
||||
pconfig.log_config(config)
|
||||
# Create printer components
|
||||
for m in [pins, mcu]:
|
||||
m.add_printer_objects(config)
|
||||
for section_config in config.get_prefix_sections(''):
|
||||
self.load_object(config, section_config.get_name(), None)
|
||||
for m in [toolhead]:
|
||||
m.add_printer_objects(config)
|
||||
# Validate that there are no undefined parameters in the config file
|
||||
pconfig.check_unused_options(config)
|
||||
def _build_protocol_error_message(self, e):
|
||||
host_version = self.start_args['software_version']
|
||||
msg_update = []
|
||||
msg_updated = []
|
||||
for mcu_name, mcu in self.lookup_objects('mcu'):
|
||||
try:
|
||||
mcu_version = mcu.get_status()['mcu_version']
|
||||
except:
|
||||
logging.exception("Unable to retrieve mcu_version from mcu")
|
||||
continue
|
||||
if mcu_version != host_version:
|
||||
msg_update.append("%s: Current version %s"
|
||||
% (mcu_name.split()[-1], mcu_version))
|
||||
else:
|
||||
msg_updated.append("%s: Current version %s"
|
||||
% (mcu_name.split()[-1], mcu_version))
|
||||
if not msg_update:
|
||||
msg_update.append("<none>")
|
||||
if not msg_updated:
|
||||
msg_updated.append("<none>")
|
||||
msg = ["MCU Protocol error",
|
||||
message_protocol_error1,
|
||||
"Your Klipper version is: %s" % (host_version,),
|
||||
"MCU(s) which should be updated:"]
|
||||
msg += msg_update + ["Up-to-date MCU(s):"] + msg_updated
|
||||
msg += [message_protocol_error2, str(e)]
|
||||
return "\n".join(msg)
|
||||
def _connect(self, eventtime):
|
||||
try:
|
||||
self._read_config()
|
||||
self.send_event("klippy:mcu_identify")
|
||||
for cb in self.event_handlers.get("klippy:connect", []):
|
||||
if self.state_message is not message_startup:
|
||||
return
|
||||
cb()
|
||||
except (self.config_error, pins.error) as e:
|
||||
logging.exception("Config error")
|
||||
self._set_state("%s\n%s" % (str(e), message_restart))
|
||||
return
|
||||
except msgproto.error as e:
|
||||
logging.exception("Protocol error")
|
||||
self._set_state(self._build_protocol_error_message(e))
|
||||
util.dump_mcu_build()
|
||||
return
|
||||
except mcu.error as e:
|
||||
logging.exception("MCU error during connect")
|
||||
self._set_state("%s%s" % (str(e), message_mcu_connect_error))
|
||||
util.dump_mcu_build()
|
||||
return
|
||||
except Exception as e:
|
||||
logging.exception("Unhandled exception during connect")
|
||||
self._set_state("Internal error during connect: %s\n%s"
|
||||
% (str(e), message_restart,))
|
||||
return
|
||||
try:
|
||||
self._set_state(message_ready)
|
||||
for cb in self.event_handlers.get("klippy:ready", []):
|
||||
if self.state_message is not message_ready:
|
||||
return
|
||||
cb()
|
||||
except Exception as e:
|
||||
logging.exception("Unhandled exception during ready callback")
|
||||
self.invoke_shutdown("Internal error during ready callback: %s"
|
||||
% (str(e),))
|
||||
def run(self):
|
||||
systime = time.time()
|
||||
monotime = self.reactor.monotonic()
|
||||
logging.info("Start printer at %s (%.1f %.1f)",
|
||||
time.asctime(time.localtime(systime)), systime, monotime)
|
||||
# Enter main reactor loop
|
||||
try:
|
||||
self.reactor.run()
|
||||
except:
|
||||
msg = "Unhandled exception during run"
|
||||
logging.exception(msg)
|
||||
# Exception from a reactor callback - try to shutdown
|
||||
try:
|
||||
self.reactor.register_callback((lambda e:
|
||||
self.invoke_shutdown(msg)))
|
||||
self.reactor.run()
|
||||
except:
|
||||
logging.exception("Repeat unhandled exception during run")
|
||||
# Another exception - try to exit
|
||||
self.run_result = "error_exit"
|
||||
# Check restart flags
|
||||
run_result = self.run_result
|
||||
try:
|
||||
if run_result == 'firmware_restart':
|
||||
for n, m in self.lookup_objects(module='mcu'):
|
||||
m.microcontroller_restart()
|
||||
if run_result == 'close_mcu_port':
|
||||
for n, m in self.lookup_objects(module='mcu'):
|
||||
m.microcontroller_close_port()
|
||||
self.send_event("klippy:disconnect")
|
||||
except:
|
||||
logging.exception("Unhandled exception during post run")
|
||||
return run_result
|
||||
def set_rollover_info(self, name, info, log=True):
|
||||
if log:
|
||||
logging.info(info)
|
||||
if self.bglogger is not None:
|
||||
self.bglogger.set_rollover_info(name, info)
|
||||
def invoke_shutdown(self, msg):
|
||||
if self.in_shutdown_state:
|
||||
return
|
||||
logging.error("Transition to shutdown state: %s", msg)
|
||||
self.in_shutdown_state = True
|
||||
self._set_state("%s%s" % (msg, message_shutdown))
|
||||
for cb in self.event_handlers.get("klippy:shutdown", []):
|
||||
try:
|
||||
cb()
|
||||
except:
|
||||
logging.exception("Exception during shutdown handler")
|
||||
logging.info("Reactor garbage collection: %s",
|
||||
self.reactor.get_gc_stats())
|
||||
def invoke_async_shutdown(self, msg):
|
||||
self.reactor.register_async_callback(
|
||||
(lambda e: self.invoke_shutdown(msg)))
|
||||
def register_event_handler(self, event, callback):
|
||||
self.event_handlers.setdefault(event, []).append(callback)
|
||||
def send_event(self, event, *params):
|
||||
return [cb(*params) for cb in self.event_handlers.get(event, [])]
|
||||
def request_exit(self, result):
|
||||
if self.run_result is None:
|
||||
self.run_result = result
|
||||
self.reactor.end()
|
||||
|
||||
|
||||
######################################################################
|
||||
# Startup
|
||||
######################################################################
|
||||
|
||||
def import_test():
|
||||
# Import all optional modules (used as a build test)
|
||||
dname = os.path.dirname(__file__)
|
||||
for mname in ['extras', 'kinematics']:
|
||||
for fname in os.listdir(os.path.join(dname, mname)):
|
||||
if fname.endswith('.py') and fname != '__init__.py':
|
||||
module_name = fname[:-3]
|
||||
else:
|
||||
iname = os.path.join(dname, mname, fname, '__init__.py')
|
||||
if not os.path.exists(iname):
|
||||
continue
|
||||
module_name = fname
|
||||
importlib.import_module(mname + '.' + module_name)
|
||||
sys.exit(0)
|
||||
|
||||
def arg_dictionary(option, opt_str, value, parser):
|
||||
key, fname = "dictionary", value
|
||||
if '=' in value:
|
||||
mcu_name, fname = value.split('=', 1)
|
||||
key = "dictionary_" + mcu_name
|
||||
if parser.values.dictionary is None:
|
||||
parser.values.dictionary = {}
|
||||
parser.values.dictionary[key] = fname
|
||||
|
||||
def main():
|
||||
usage = "%prog [options] <config file>"
|
||||
opts = optparse.OptionParser(usage)
|
||||
opts.add_option("-i", "--debuginput", dest="debuginput",
|
||||
help="read commands from file instead of from tty port")
|
||||
opts.add_option("-I", "--input-tty", dest="inputtty",
|
||||
default='/tmp/printer',
|
||||
help="input tty name (default is /tmp/printer)")
|
||||
opts.add_option("-a", "--api-server", dest="apiserver",
|
||||
help="api server unix domain socket filename")
|
||||
opts.add_option("-l", "--logfile", dest="logfile",
|
||||
help="write log to file instead of stderr")
|
||||
opts.add_option("-v", action="store_true", dest="verbose",
|
||||
help="enable debug messages")
|
||||
opts.add_option("-o", "--debugoutput", dest="debugoutput",
|
||||
help="write output to file instead of to serial port")
|
||||
opts.add_option("-d", "--dictionary", dest="dictionary", type="string",
|
||||
action="callback", callback=arg_dictionary,
|
||||
help="file to read for mcu protocol dictionary")
|
||||
opts.add_option("--import-test", action="store_true",
|
||||
help="perform an import module test")
|
||||
options, args = opts.parse_args()
|
||||
if options.import_test:
|
||||
import_test()
|
||||
if len(args) != 1:
|
||||
opts.error("Incorrect number of arguments")
|
||||
start_args = {'config_file': args[0], 'apiserver': options.apiserver,
|
||||
'start_reason': 'startup'}
|
||||
|
||||
debuglevel = logging.INFO
|
||||
if options.verbose:
|
||||
debuglevel = logging.DEBUG
|
||||
if options.debuginput:
|
||||
start_args['debuginput'] = options.debuginput
|
||||
debuginput = open(options.debuginput, 'rb')
|
||||
start_args['gcode_fd'] = debuginput.fileno()
|
||||
else:
|
||||
start_args['gcode_fd'] = util.create_pty(options.inputtty)
|
||||
if options.debugoutput:
|
||||
start_args['debugoutput'] = options.debugoutput
|
||||
start_args.update(options.dictionary)
|
||||
bglogger = None
|
||||
if options.logfile:
|
||||
start_args['log_file'] = options.logfile
|
||||
bglogger = queuelogger.setup_bg_logging(options.logfile, debuglevel)
|
||||
else:
|
||||
logging.getLogger().setLevel(debuglevel)
|
||||
logging.info("Starting Klippy...")
|
||||
start_args['software_version'] = util.get_git_version()
|
||||
start_args['cpu_info'] = util.get_cpu_info()
|
||||
if bglogger is not None:
|
||||
versions = "\n".join([
|
||||
"Args: %s" % (sys.argv,),
|
||||
"Git version: %s" % (repr(start_args['software_version']),),
|
||||
"CPU: %s" % (start_args['cpu_info'],),
|
||||
"Python: %s" % (repr(sys.version),)])
|
||||
logging.info(versions)
|
||||
elif not options.debugoutput:
|
||||
logging.warning("No log file specified!"
|
||||
" Severe timing issues may result!")
|
||||
gc.disable()
|
||||
|
||||
# Start Printer() class
|
||||
while 1:
|
||||
if bglogger is not None:
|
||||
bglogger.clear_rollover_info()
|
||||
bglogger.set_rollover_info('versions', versions)
|
||||
gc.collect()
|
||||
main_reactor = reactor.Reactor(gc_checking=True)
|
||||
printer = Printer(main_reactor, bglogger, start_args)
|
||||
res = printer.run()
|
||||
if res in ['exit', 'error_exit']:
|
||||
break
|
||||
time.sleep(1.)
|
||||
main_reactor.finalize()
|
||||
main_reactor = printer = None
|
||||
logging.info("Restarting printer")
|
||||
start_args['start_reason'] = res
|
||||
|
||||
if bglogger is not None:
|
||||
bglogger.stop()
|
||||
|
||||
if res == 'error_exit':
|
||||
sys.exit(-1)
|
||||
|
||||
if __name__ == '__main__':
|
||||
main()
|
||||
Reference in New Issue
Block a user