# Probe calibration
|
||||
|
||||
This document describes the method for calibrating the X, Y, and Z
|
||||
offsets of an "automatic z probe" in Klipper. This is useful for users
|
||||
that have a `[probe]` or `[bltouch]` section in their config file.
|
||||
|
||||
## Calibrating probe X and Y offsets
|
||||
|
||||
To calibrate the X and Y offset, navigate to the OctoPrint "Control"
|
||||
tab, home the printer, and then use the OctoPrint jogging buttons to
|
||||
move the head to a position near the center of the bed.
|
||||
|
||||
Place a piece of blue painters tape (or similar) on the bed underneath
|
||||
the probe. Navigate to the OctoPrint "Terminal" tab and issue a PROBE
|
||||
command:
|
||||
```
|
||||
PROBE
|
||||
```
|
||||
Place a mark on the tape directly under where the probe is (or use a
|
||||
similar method to note the location on the bed).
|
||||
|
||||
Issue a `GET_POSITION` command and record the toolhead XY location
|
||||
reported by that command. For example if one sees:
|
||||
```
|
||||
Recv: // toolhead: X:46.500000 Y:27.000000 Z:15.000000 E:0.000000
|
||||
```
|
||||
then one would record a probe X position of 46.5 and probe Y position
|
||||
of 27.
|
||||
|
||||
After recording the probe position, issue a series of G1 commands
|
||||
until the nozzle is directly above the mark on the bed. For example,
|
||||
one might issue:
|
||||
```
|
||||
G1 F300 X57 Y30 Z15
|
||||
```
|
||||
to move the nozzle to an X position of 57 and Y of 30. Once one finds
|
||||
the position directly above the mark, use the `GET_POSITION` command
|
||||
to report that position. This is the nozzle position.
|
||||
|
||||
The x_offset is then the `nozzle_x_position - probe_x_position` and
|
||||
y_offset is similarly the `nozzle_y_position - probe_y_position`.
|
||||
Update the printer.cfg file with the given values, remove the
|
||||
tape/marks from the bed, and then issue a `RESTART` command so that
|
||||
the new values take effect.
|
||||
|
||||
## Calibrating probe Z offset
|
||||
|
||||
Providing an accurate probe z_offset is critical to obtaining high
|
||||
quality prints. The z_offset is the distance between the nozzle and
|
||||
bed when the probe triggers. The Klipper `PROBE_CALIBRATE` tool can be
|
||||
used to obtain this value - it will run an automatic probe to measure
|
||||
the probe's Z trigger position and then start a manual probe to obtain
|
||||
the nozzle Z height. The probe z_offset will then be calculated from
|
||||
these measurements.
|
||||
|
||||
Start by homing the printer and then move the head to a position near
|
||||
the center of the bed. Navigate to the OctoPrint terminal tab and run
|
||||
the `PROBE_CALIBRATE` command to start the tool.
|
||||
|
||||
This tool will perform an automatic probe, then lift the head, move
|
||||
the nozzle over the location of the probe point, and start the manual
|
||||
probe tool. If the nozzle does not move to a position above the
|
||||
automatic probe point, then `ABORT` the manual probe tool and perform
|
||||
the XY probe offset calibration described above.
|
||||
|
||||
Once the manual probe tool starts, follow the steps described at
|
||||
["the paper test"](Bed_Level.md#the-paper-test)) to determine the
|
||||
actual distance between the nozzle and bed at the given location. Once
|
||||
those steps are complete one can `ACCEPT` the position and save the
|
||||
results to the config file with:
|
||||
```
|
||||
SAVE_CONFIG
|
||||
```
|
||||
|
||||
Note that if a change is made to the printer's motion system, hotend
|
||||
position, or probe location then it will invalidate the results of
|
||||
PROBE_CALIBRATE.
|
||||
|
||||
If the probe has an X or Y offset and the bed tilt is changed (eg, by
|
||||
adjusting bed screws, running DELTA_CALIBRATE, running Z_TILT_ADJUST,
|
||||
running QUAD_GANTRY_LEVEL, or similar) then it will invalidate the
|
||||
results of PROBE_CALIBRATE. After making any of the above adjustments
|
||||
it will be necessary to run PROBE_CALIBRATE again.
|
||||
|
||||
If the results of PROBE_CALIBRATE are invalidated, then any previous
|
||||
[bed mesh](Bed_Mesh.md) results that were obtained using the probe are
|
||||
also invalidated - it will be necessary to rerun BED_MESH_CALIBRATE
|
||||
after recalibrating the probe.
|
||||
|
||||
## Repeatability check
|
||||
|
||||
After calibrating the probe X, Y, and Z offsets it is a good idea to
|
||||
verify that the probe provides repeatable results. Start by homing the
|
||||
printer and then move the head to a position near the center of the
|
||||
bed. Navigate to the OctoPrint terminal tab and run the
|
||||
`PROBE_ACCURACY` command.
|
||||
|
||||
This command will run the probe ten times and produce output similar
|
||||
to the following:
|
||||
```
|
||||
Recv: // probe accuracy: at X:0.000 Y:0.000 Z:10.000
|
||||
Recv: // and read 10 times with speed of 5 mm/s
|
||||
Recv: // probe at -0.003,0.005 is z=2.506948
|
||||
Recv: // probe at -0.003,0.005 is z=2.519448
|
||||
Recv: // probe at -0.003,0.005 is z=2.519448
|
||||
Recv: // probe at -0.003,0.005 is z=2.506948
|
||||
Recv: // probe at -0.003,0.005 is z=2.519448
|
||||
Recv: // probe at -0.003,0.005 is z=2.519448
|
||||
Recv: // probe at -0.003,0.005 is z=2.506948
|
||||
Recv: // probe at -0.003,0.005 is z=2.506948
|
||||
Recv: // probe at -0.003,0.005 is z=2.519448
|
||||
Recv: // probe at -0.003,0.005 is z=2.506948
|
||||
Recv: // probe accuracy results: maximum 2.519448, minimum 2.506948, range 0.012500, average 2.513198, median 2.513198, standard deviation 0.006250
|
||||
```
|
||||
|
||||
Ideally the tool will report an identical maximum and minimum value.
|
||||
(That is, ideally the probe obtains an identical result on all ten
|
||||
probes.) However, it's normal for the minimum and maximum values to
|
||||
differ by one Z "step distance" or up to 5 microns (.005mm). A "step
|
||||
distance" is
|
||||
`rotation_distance/(full_steps_per_rotation*microsteps)`. The distance
|
||||
between the minimum and the maximum value is called the range. So, in
|
||||
the above example, since the printer uses a Z step distance of .0125,
|
||||
a range of 0.012500 would be considered normal.
|
||||
|
||||
If the results of the test show a range value that is greater than 25
|
||||
microns (.025mm) then the probe does not have sufficient accuracy for
|
||||
typical bed leveling procedures. It may be possible to tune the probe
|
||||
speed and/or probe start height to improve the repeatability of the
|
||||
probe. The `PROBE_ACCURACY` command allows one to run tests with
|
||||
different parameters to see their impact - see the
|
||||
[G-Codes document](G-Codes.md#probe_accuracy) for further details. If
|
||||
the probe generally obtains repeatable results but has an occasional
|
||||
outlier, then it may be possible to account for that by using multiple
|
||||
samples on each probe - read the description of the probe `samples`
|
||||
config parameters in the [config reference](Config_Reference.md#probe)
|
||||
for more details.
|
||||
|
||||
If new probe speed, samples count, or other settings are needed, then
|
||||
update the printer.cfg file and issue a `RESTART` command. If so, it
|
||||
is a good idea to
|
||||
[calibrate the z_offset](#calibrating-probe-z-offset) again. If
|
||||
repeatable results can not be obtained then don't use the probe for
|
||||
bed leveling. Klipper has several manual probing tools that can be
|
||||
used instead - see the [Bed Level document](Bed_Level.md) for further
|
||||
details.
|
||||
|
||||
## Location Bias Check
|
||||
|
||||
Some probes can have a systemic bias that corrupts the results of the
|
||||
probe at certain toolhead locations. For example, if the probe mount
|
||||
tilts slightly when moving along the Y axis then it could result in
|
||||
the probe reporting biased results at different Y positions.
|
||||
|
||||
This is a common issue with probes on delta printers, however it can
|
||||
occur on all printers.
|
||||
|
||||
One can check for a location bias by using the `PROBE_CALIBRATE`
|
||||
command to measuring the probe z_offset at various X and Y locations.
|
||||
Ideally, the probe z_offset would be a constant value at every printer
|
||||
location.
|
||||
|
||||
For delta printers, try measuring the z_offset at a position near the
|
||||
A tower, at a position near the B tower, and at a position near the C
|
||||
tower. For cartesian, corexy, and similar printers, try measuring the
|
||||
z_offset at positions near the four corners of the bed.
|
||||
|
||||
Before starting this test, first calibrate the probe X, Y, and Z
|
||||
offsets as described at the beginning of this document. Then home the
|
||||
printer and navigate to the first XY position. Follow the steps at
|
||||
[calibrating probe Z offset](#calibrating-probe-z-offset) to run the
|
||||
`PROBE_CALIBRATE` command, `TESTZ` commands, and `ACCEPT` command, but
|
||||
do not run `SAVE_CONFIG`. Note the reported z_offset found. Then
|
||||
navigate to the other XY positions, repeat these `PROBE_CALIBRATE`
|
||||
steps, and note the reported z_offset.
|
||||
|
||||
If the difference between the minimum reported z_offset and the
|
||||
maximum reported z_offset is greater than 25 microns (.025mm) then the
|
||||
probe is not suitable for typical bed leveling procedures. See the
|
||||
[Bed Level document](Bed_Level.md) for manual probe alternatives.
|
||||
|
||||
## Temperature Bias
|
||||
|
||||
Many probes have a systemic bias when probing at different
|
||||
temperatures. For example, the probe may consistently trigger at a
|
||||
lower height when the probe is at a higher temperature.
|
||||
|
||||
It is recommended to run the bed leveling tools at a consistent
|
||||
temperature to account for this bias. For example, either always run
|
||||
the tools when the printer is at room temperature, or always run the
|
||||
tools after the printer has obtained a consistent print temperature.
|
||||
In either case, it is a good idea to wait several minutes after the
|
||||
desired temperature is reached, so that the printer apparatus is
|
||||
consistently at the desired temperature.
|
||||
|
||||
To check for a temperature bias, start with the printer at room
|
||||
temperature and then home the printer, move the head to a position
|
||||
near the center of the bed, and run the `PROBE_ACCURACY` command. Note
|
||||
the results. Then, without homing or disabling the stepper motors,
|
||||
heat the printer nozzle and bed to printing temperature, and run the
|
||||
`PROBE_ACCURACY` command again. Ideally, the command will report
|
||||
identical results. As above, if the probe does have a temperature bias
|
||||
then be careful to always use the probe at a consistent temperature.
|
||||