# This file provides example config file settings for use on a printer
|
||||
# that uses a Z probe instead of a traditional Z endstop switch. This
|
||||
# file is just a "snippet" of config sections - it must be added to a
|
||||
# config file containing the configuration of the rest of the printer.
|
||||
|
||||
# Be sure to review and update this config with the appropriate pins
|
||||
# and coordinates for your printer.
|
||||
|
||||
# See docs/Config_Reference.md for a description of parameters.
|
||||
|
||||
# Define a probe
|
||||
[probe]
|
||||
pin: ar30
|
||||
z_offset: 2.345
|
||||
|
||||
# Example settings to add to stepper_z section
|
||||
[stepper_z]
|
||||
endstop_pin: probe:z_virtual_endstop
|
||||
position_min: -2 # The Z carriage may need to travel below the Z=0
|
||||
# homing point if the bed has a significant tilt.
|
||||
|
||||
# The safe_z_home section modifies the default G28 behavior
|
||||
[safe_z_home]
|
||||
home_xy_position: 100, 100
|
||||
speed: 50
|
||||
z_hop: 15
|
||||
z_hop_speed: 5
|
||||
|
||||
# Example bed_tilt config section
|
||||
[bed_tilt]
|
||||
points:
|
||||
100, 100
|
||||
10, 10
|
||||
10, 100
|
||||
10, 190
|
||||
100, 10
|
||||
100, 190
|
||||
190, 10
|
||||
190, 100
|
||||
190, 190
|
||||
|
||||
# Example bed_mesh config section
|
||||
[bed_mesh]
|
||||
mesh_min: 20, 20
|
||||
mesh_max: 200, 200
|
||||
probe_count: 4, 4
|
||||