mirror of
https://github.com/QIDITECH/QIDI_Q1_Pro.git
synced 2026-01-30 23:48:43 +03:00
Update README.md
This commit is contained in:
19
README.md
19
README.md
@@ -8,19 +8,26 @@ QIDI_Q1_Pro is a server-side application designed specifically for the Q1_Pro mo
|
|||||||
For convenience, QIDI provides version-specific packaged files. Please download the necessary compressed package file prefixed with "Q1_Pro." We offer several versions of the source code tailored to different needs; select the appropriate branch for download, with each branch name reflecting the corresponding version.
|
For convenience, QIDI provides version-specific packaged files. Please download the necessary compressed package file prefixed with "Q1_Pro." We offer several versions of the source code tailored to different needs; select the appropriate branch for download, with each branch name reflecting the corresponding version.
|
||||||
|
|
||||||
|
|
||||||
## Update Content for Version 4.4.18
|
## Update Content for Version 4.4.19
|
||||||
|
|
||||||
**Note:** After updating, the Klipper configuration file will be replaced. The previous configuration file will be backed up as `printer_{datetime}.cfg`, printer recalibration will be required.
|
**Note:** After updating, the Klipper configuration file will be replaced. The previous configuration file will be backed up as `printer_{datetime}.cfg`, printer recalibration will be required.
|
||||||
|
|
||||||
**1.** Added port 80 to Fluidd.
|
**1.** Modified platform calibration logic
|
||||||
|
|
||||||
**2.** Fixed the issue where power failure resume could not work.
|
During platform tilt calibration, the machine performs a sensorless homing downwards to ensure the heights of the left and right Z axes are consistent.
|
||||||
|
|
||||||
**3.** Fixed the issue with USB device unmounting failing in certain cases.
|
**2.** Optimized Gcode processing logic
|
||||||
|
|
||||||
**4.** Added Ethernet switching feature.
|
We have increased the processing priority of certain Gcodes, such as SET_GCODE_OFFSET, to ensure they are executed immediately upon input. However, due to the presence of a move queue in the toolhead, which temporarily stores some parsed movements, the effect is not immediate. We plan to continue improving this in future versions.
|
||||||
|
|
||||||
**5.** Added error prompt for QR code generation.
|
**3.** Added functionality to move without homing
|
||||||
|
|
||||||
|
We have noticed that in some cases, such as when printing is unexpectedly interrupted, users may want to move the Z-axis to facilitate the removal of a broken model upon machine restart. Typically, this would require homing before movement, but homing can be obstructed by the model. Therefore, we have added the capability to move the Z-axis without homing and provided corresponding prompts.
|
||||||
|
|
||||||
|
**4.** Fixed issues with camera loading under specific circumstances
|
||||||
|
**5.** Fixed display issues with connected WiFi name
|
||||||
|
|
||||||
|
We also addressed an issue where the display of connected WiFi names containing Unicode characters appeared blank, and this has been fixed.
|
||||||
|
|
||||||
**6.** Adjusted default parameters.
|
**6.** Adjusted default parameters.
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue
Block a user